A PHP Error was encountered

Severity: Warning

Message: fopen(/tmp/ci_session1d234c4578adf19ddf66162be6f70685b8b547f7): failed to open stream: Disk quota exceeded

Filename: drivers/Session_files_driver.php

Line Number: 176

Backtrace:

File: /home/hitechzo/public_html/hospilab.com/application/controllers/Home.php
Line: 9
Function: __construct

File: /home/hitechzo/public_html/hospilab.com/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /tmp)

Filename: Session/Session.php

Line Number: 143

Backtrace:

File: /home/hitechzo/public_html/hospilab.com/application/controllers/Home.php
Line: 9
Function: __construct

File: /home/hitechzo/public_html/hospilab.com/index.php
Line: 315
Function: require_once

Hospilab | Hospilab Equipment | Hospilab Supplies
Distributor
Mobile X-ray machine KMX-B101

Mobile X-ray machine KMX-B101

www.hospilab.com | info@hospilab.net

Overview

Mobile X-ray machine KMX-B101 is an advanced x-ray imaging modality designed for better mobility and manageability during intra-hospital transit. System is equipped with 50 pre-set exposure programs with automatic back-up memory and multiple protection functions for safer use. Automatic self-test setting and alarming reduces need for maintenance. Proximal as well as remote accessibility controllers make it more versatile to use.

Specifications :
Inverter Frequency 50 kHz
Tube Voltage 40 kV – 120 kV (interval 1 kV)
Operational Access Wired/Wireless Control
Current 1.0–180 mAs (46 steps)
Power Rating 5 kVA
Internal Resistance ≤ 1 Ω
Exposure Parameters
VoltageCurrentRadiographic Density
40 kV - 49 kV100 mA1 mAs - 180 mAs
50 kV - 59 kV77 mA1 mAs - 140 mAs
60 kV - 69 kV64 mA1 mAs - 125 mAs
70 kV - 79 kV55 mA1 mAs - 110 mAs
80 kV - 89 kV49 mA1 mAs - 100 mAs
90 kV - 99 kV44 mA1 mAs - 80 mAs
100 kV - 109 kV32 mA1 mAs - 63 mAs
110 kV - 120 kV25 mA1 mAs - 50 mAs
Power Supply Voltage : 220 V ±10% Frequency : 50Hz
Built–in Battery Rechargeable Lithium
Dimensions 1500 x 750 x 1850 mm
Weight 355 Kgs

 

Features :
  • High frequency X-ray generation
  • High quality X-ray monolight technology
  • Exposure current: 1.0-180mAs (46 steps)
  • 50 built-in exposure control programs
  • Accurate X-ray penetration
  • Flexible and easy source orientation
  • Symmetrical collimator
  • Mobile table (optional)
  • Built-in rechargeable battery
Applications :

Used throughout the hospital from in-patient, to NICU, operating room, and emergency room as well as polyclinics to perform projection radiography readily on bedbound or critical patients for convenience.

  • CB03-4516 VALIANT DR NW, Calgary, AB T3K 0Y1, Canada
  • Email: info@hospilab.com | Website: www.hospilab.com
    Phone: +1 587 885 1415